2 Remote control commands
780/781 pH/Ion Meter - Operation via RS232 17
.TempType Temperature sensor type read only
.DateTime Date and time of calibration read only
.CalInterval Calibration interval read only
.Variance Statistics parameter read only
.BufferType Type of calibration buffer set read only
.NoBuffer Number of calibration buffers used read only
.CalTab Calibration buffer table
.Select Select and edit buffer table original, delete n, reset cal
.DeleteN Delete measurement with buffer n 1...9
.MeasData
.1 Buffer 1
.pH Nominal pH value read only
.U Measured potential read only
.dpH Calculated deviation read only
up to 9
.ElTestData Electrode test data
.ElectrodeId Identification of tested electrode read only
.MethodId Name of test method read only
.ElType Type of pH electrode read only
.Temp Temperature read only
.TempType Type of temperature sensor read only
.DateTime Date and time of electrode test read only
.Message Result of electrode test read only
.ConcCalData Cal. data for direct concentration measurement (781 only)
.IonType Ion type read only
.ElectrodeId Identification of calibrated electrode read only
.MethodId Name of calibration method read only
.Slope Slope -999.9...-59.2...999.9
.E0 Electrode zero point [mV] -999.9...0.0...999.9
.CBlank Blanc value 0.0...1.0E+30
.CalTemp Calibration temperature read only
.TempType Type of temperature sensor read only
.DateTime Date and time of calibration read only
.CalInterval Calibration interval read only
.Variance Statistics parameter read only
.NoStd Number of calibration standards used read only
.CalTab Calibration standard table
.Select Select and edit standard table original, delete n, reset cal
.DeleteN Delete measurement with standard n 1...19
.MeasData
.1 Standard 1
.conc Nominal concentration read only
.U Measured potential read only
.dconc Calculated deviation read only
up to 19
.AddData Data of standard addition or sample addition for conc. measurement (781 only)
.IonType Ion type read only
.MeasType Type of concentration measurement read only
.ElectrodeId Identification of electrode read only
.Variance Statistics parameter read only
.Slope Slope -999.9...59.2...999.9
.E0 Electrode zero point [mV] -999.9...0.0...999.9
.Conc Measured concentration read only
.DateTime Date and time of measurement read only
.MethodId Method name read only
.Temp Measuring temperature read only
.TempType Type of temperature sensor read only
.VTotal Total start volume read only