2 Remote control commands
780/781 pH/Ion Meter - Operation via RS232 17
│ ├ .TempType Temperature sensor type read only
│ ├ .DateTime Date and time of calibration read only
│ ├ .CalInterval Calibration interval read only
│ ├ .Variance Statistics parameter read only
│ ├ .BufferType Type of calibration buffer set read only
│ ├ .NoBuffer Number of calibration buffers used read only
│ ├ .CalTab Calibration buffer table
│ │ ├ .Select Select and edit buffer table original, delete n, reset cal
│ │ └ .DeleteN Delete measurement with buffer n 1...9
│ └ .MeasData
│ ├ .1 Buffer 1
│ │ ├ .pH Nominal pH value read only
│ │ ├ .U Measured potential read only
│ │ └ .dpH Calculated deviation read only
│ └ up to 9
├ .ElTestData Electrode test data
│ ├ .ElectrodeId Identification of tested electrode read only
│ ├ .MethodId Name of test method read only
│ ├ .ElType Type of pH electrode read only
│ ├ .Temp Temperature read only
│ ├ .TempType Type of temperature sensor read only
│ ├ .DateTime Date and time of electrode test read only
│ └ .Message Result of electrode test read only
├ .ConcCalData Cal. data for direct concentration measurement (781 only)
│ ├ .IonType Ion type read only
│ ├ .ElectrodeId Identification of calibrated electrode read only
│ ├ .MethodId Name of calibration method read only
│ ├ .Slope Slope -999.9...-59.2...999.9
│ ├ .E0 Electrode zero point [mV] -999.9...0.0...999.9
│ ├ .CBlank Blanc value 0.0...1.0E+30
│ ├ .CalTemp Calibration temperature read only
│ ├ .TempType Type of temperature sensor read only
│ ├ .DateTime Date and time of calibration read only
│ ├ .CalInterval Calibration interval read only
│ ├ .Variance Statistics parameter read only
│ ├ .NoStd Number of calibration standards used read only
│ ├ .CalTab Calibration standard table
│ │ ├ .Select Select and edit standard table original, delete n, reset cal
│ │ └ .DeleteN Delete measurement with standard n 1...19
│ └ .MeasData
│ ├ .1 Standard 1
│ │ ├ .conc Nominal concentration read only
│ │ ├ .U Measured potential read only
│ │ └ .dconc Calculated deviation read only
│ └ up to 19
├ .AddData Data of standard addition or sample addition for conc. measurement (781 only)
│ ├ .IonType Ion type read only
│ ├ .MeasType Type of concentration measurement read only
│ ├ .ElectrodeId Identification of electrode read only
│ ├ .Variance Statistics parameter read only
│ ├ .Slope Slope -999.9...59.2...999.9
│ ├ .E0 Electrode zero point [mV] -999.9...0.0...999.9
│ ├ .Conc Measured concentration read only
│ ├ .DateTime Date and time of measurement read only
│ ├ .MethodId Method name read only
│ ├ .Temp Measuring temperature read only
│ ├ .TempType Type of temperature sensor read only
│ ├ .VTotal Total start volume read only